Jinding precision air conditioner 90~100KW
Products Features:
Reliable: constant temperature, constant humidity, clean and precise environmental control to ensure the normal and efficient operation of the main equipment
The structure and function design of all-weather uninterrupted and stable operation ensures the safe operation environment of the main equipment
All components and unit performance have been strictly tested before leaving the factory, which is stable and reliable.
Energy saving: The refrigeration energy efficiency ratio of the compressors of the medium and large-scale computer room air conditioners of Aite Net Energy is above 3.2, and the energy efficiency of chilled water cooling is above 25.
International best high-efficiency compressors and fans, high efficiency and energy saving
"M type (double A)/W type (double V)" evaporator, the highest heat exchange efficiency
Independent air duct design, minimum air duct resistance and minimum fan power
Optimal CFD air duct optimization design, minimum air duct resistance and minimum fan power
Outdoor fan frequency conversion speed regulation, energy saving, high efficiency and long life
High-efficiency management control, avoiding competitive operation, and inputting cooling capacity on demand
Easy maintenance: full front maintenance design
Configurable 7-inch touch high-definition large screen display
Metal frame air filter, repeated cleaning and use, low maintenance cost
Automatic flushing of humidifiers to reduce maintenance effort
Modular design, minimum spare parts, low maintenance cost
The differential pressure monitoring automatically prompts the filter to be dirty and blocked, and the maintenance is timely and convenient
Easy to choose: Wide range of cooling capacity: air cooling (25kW~100kW), chilled water (30kW~200kW)
Many cooling methods: air cooling, water cooling & glycol cooling, single & double coil chilled water, air cooling & water cooling dual cooling source, air cooling & water cooling natural cooling, fluorine pump natural cooling
There are many ways of air supply: air supply on the hood, air supply on the air duct, air supply under the floor, and air supply under the sinking floor
Various types of refrigerants: There are a variety of refrigerants to choose from, and it is recommended to use R410A environmentally friendly refrigerant units that are more friendly to the global environment
There are many humidification methods: the unit has the humidification function, and is equipped with an electrode humidifier or a far-infrared humidifier.
Wide outdoor temperature range: standard (-20℃~50℃), low temperature (-40℃~50℃)